Current transformer
Current transformer 6A / DC, AC, pulse / multi-range / minimum offset drift
CHF 15.90 excl. VAT, plus shipping costs
Item no:
LXSR 6-NPS
In stock: Available to order
Description
- DC, AC and pulse current measurement with galvanic isolation
- Current measurements from 2 to 25 ARMS nominal
- 3 models (6A, 15A and 25A)
- Low offset drift
- Reference Access OUT & IN (0.5 to 2.75V) on separate pin
- Integrated primary conductor + additional primary conductor opening D=3.2mm
- Attractive price
- 5 year guarantee
- Compact design
- Manufacturer LEM
Technical data
- Unipolar supply 0, +5 V
- Insulation test voltage: up to 4.3KVRMS / 50 Hz / 1 min
- Closed loop reverb effect technology based on LEM's proprietary and patented ASIC
- Operating temperature range: -40°C to + 85°C
- Voltage output (0.625V at Ipn)
- Short response time 0.4 µs
Note
- 3 different primary connection configurations are possible for each model, allowing currents of 1/2 or 1/3 of Ipn to be measured with high resolution
- Bipolar current measurement despite unipolar voltage supply 0/+5V
- 100% compatible with the previous LEM series LTSR
Additional information
| Current transformer | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
| LEDs | ||||||||||||||||||||||||||
|
||||||||||||||||||||||||||
Data sheets
| Data sheet LXSR | PDF(1.09 MB) |
|---|
Downloads
| 3D Step File LXSR | Zip file (499.19 KB) |
|---|
We would be happy to advise you personally
Our technical support team will be happy to answer any questions you may have about our products. Our competent product specialists with project experience will accompany you conscientiously in your projects. It is important to us to offer our customers top service at all times.